Expt 2: Characterization of Laminar Premixed Flame using Chemiluminescence Sensor
Aim
Intro
About Exp
Results
Conclusions
Precautions
FAQs
References
Test Details
Chemiluminescence signatures of OH
*
and CH
*
.
Determination of marker for equivalence ratio.
Determination of marker for flame temperature.
CH
*
chemiluminescence and flame temperature
CH
*
intensity and temperature variations with equivalence ratio are similar.
However, CH
*
and temperature peaks do not occur at same equivalence ratio.
Hence, CH
*
might
not
be a good marker for flame temperature.
OH
*
chemiluminescence and flame temperature
OH
*
intensity and temperature variations with equivalence ratio are similar.
Further, OH
*
and temperature peaks occur at nearly same equivalence ratio.
Hence, OH
*
is a good marker for flame temperature.
OH
*
intensity-flame temperature correlation
OH
*
intensity normalized using its peak value and temperature variations are correlated using the following expression (R
2
= 0.97).
The correlation is based on data obtained for ? = 0.85-1.35.